The use of pacemakers in infants and children

  • Miro Kosin
Keywords: pacemakers, infants and children, congenital heart defects

Abstract

Background: To review retrospectively our experience with pediatric cardiac pacing with an emphasis on specific problems in pacemaker implantation in infants and children.

Methods: Between April 1977 and March 2005 ninety-one child underwent permanent pacemaker implantation, 46 boys (50.5%) and 45 girls (49.5) with a mean age of 7.9 years (the oldest 17 years and the youngest 1 day). The age of the children at the time of implantation was 2 to 9 years in one half and 14 to 17 years in one fourth of them. Five children were younger than one month and three of them younger than one week. The indications for permanent pacing were complete atrioventricular block (CAVB) in more than half patients, sick sinus syndrome in one fourth and CAVB following open heart surgery in nine. The mean time for elective battery replacement was 6.5 years after the implantation. In one third of the children the battery was replaced before the end of the fifth year after the implantation and after seven years in more than half of the patients. Epicardial leads and left anterior thoracotomy or subxyphoid approach were used at the beginning. From the year 1980 we prefered transvenous leads. Modern epicardial steroideluting leads demonstrated relatively stable acute and chronic pacing and sensing tresholds. VVI/R pacemaker was the pacemaker of choice at the first implantation and we upgraded the pacing at the time of the elective battery replacement. Children with VDD pacemakers needed sometimes upgrading of pacing sooner because of the inappropriate atrial sensing and AV synchronyzation.

Conclusions: Better quality pacing leads and smaller but more powerful pacemaker generators with autocapturecontrolled pacing options became more and more attractive for our little patients because of better implantation facilities, substantial energy savings and battery life prolongation.

Downloads

Download data is not yet available.

References

Boutjdir M. Molecular and ionic basis of congenital complete heart block. Trends Cardiovasc Med 2000; 10: 114–22.

Beauford-Krol GCM, Mulder H, Nagelkerke D, et al. Comparison of longevity, pacing and sensing characteristics of steroid-eluting epicardial versus conventional endocardial pacing leads in children. J Thorac Cardiovasc Surg 1999; 117: 523–8.

Kammeraad JA, Rosenthal E, Bostock J, Rogers J, Sreeram N. Endocardial pacemaker implantation in infants weighting < or = 10 kilograms. Pacing Clin Electrophysiol 2004; 27: 1466–74.

Sachweh JS, Vazquez-Jimenez JF, Schondube FA, Daebritz SH, Dorge H, Muhler EG, Messmer BJ. Tventy years experience with pediatric pacing: epicardial and transvenous stimulation. Eur J Cardiothorac Surg 2000; 17: 455–61.

Udink ten Cate FE, Breur JM, Cohen MI, Boramanand N, Kapusta L, Crosson JE, et al. Dilated cardiomyopathy in isolated congenital complete atrioventricular block: early and long-term risk in children. J AM Coll Cardiol 2001; 37: 1129–34.

Thomson JD, Blackburn ME, Van Doorn C, Nicholls A, Watterson KG. Pacing activity, patient and lead survival over 20 years of permanent epicardial pacing in children. Ann Thorac Surg 2004; 77: 1366–70.

Sliz NB Jr, Johns JA. Cardiac pacing in infants and children. Cardiol Rev 2000; 8: 223–39.

Horenstein MS, Karpawich PP. Pacemaker syndrome in the young: do children need dual chamber as the initial pacing mode? Pacing Clin Electrophysiol 2004; 27: 600–5.

Ovsyscher IE, Katz A, Rosenheck S, Bondy C. Single lead VDD pacing: multicenter study. Pacing Clin Electrophysiol 1996; 19: 1768–71.

Bostan OM, Celiker A, Karagoz T, Ozer S, Ozme S. Dual chamber cardiac pacing in children: Single chamber pacing dual chamber sensing cardiac pacemaker or dual chamber pacing and sensing cardiac pacemaker? Pediatr Int 2002; 44: 635–40.

Bauersfeld U, Nowak B, Molinari L, Malm T, Kampmann C, Schonbeck MH, Schuller H. Low-energy epicardial pacing in children: the benefit of autocapture. Ann Thorac Surg 1999; 68: 1380–3.

Kucukosmanoglu O, Celiker A, Ozer S, Karagoz T. Compatibility of automatic treshold tracking pacemakers with previously implanted pacing leads in children. Pacing Clin Electrophysiol 2002; 25: 1624–7.

Silvetti MS, Drago F, Pastore E, Turchetta A, Calzolari A, Di Donato RM, Ragonese P. Does chronic pacing affect exercise capacity after Mustard operation for transposition of the great arteries? Pediatr Cardiol 2002; 23: 3–8.

How to Cite
1.
Kosin M. The use of pacemakers in infants and children. TEST ZdravVestn [Internet]. 1 [cited 5Aug.2024];74. Available from: http://vestnik-dev.szd.si/index.php/ZdravVest/article/view/2185
Section
Test Section