Surgical complications after pacemaker implantations

  • Jože Antonič
  • Anton Crnjac
Keywords: pacemaker, early and late surgical complications

Abstract

Abstract: With the development of science and technology, cardiac pace maker implantation has become most frequently performed operative procedure on the heart. The initial surgically rather complicated transthoracic approach and epicardial electrode cathether insertion was followed by the technically much easier transvenous approach and cathether insertion at the optimal site of the endocardium. In recent years, video-assisted thoracic surgery has established its undisputed place in epicardial electrode cathether insertion. Due to its lower morbidity, it replaced the much more aggressive thoracotomy and sternotomy. Preoperative patient preparation improved, the multidisciplinary approach to pathology solution prevailed and consequently the number of complications decreased. Presented are some of the most frequent and – despite the improved operative technique – unavoidable surgical complications, as well as the surgical complications occuring in cardiac pace maker insertions performed at the Maribor Teaching Hospital Department of Thoracic Surgery during the 5-year period of 2000–2004.

Downloads

Download data is not yet available.

References

Senning A. Discussion of a paper by Stephenson SE Jr, Edwards WH, Jolly PC, Scott HW: Physiologic P-wave stimulator. J Thorac Cardiovasc Surg 1959; 38: 639–42.

Furman S, Schwedl JB. An intracardiac pacemaker for Stokes-Adams seizures. N Engl J Med 1959; 261: 948–52.

Sutton R, Bourgeois I. Techniques of implantation. In: Sutton R, Bourgeois I, eds: The fundations of cardiac pacing: An illustrated practical guide to basic pacing. Vol I, pt I Mt Kisco, NY: Futura:1991.

Krasna MJ, Buser GA, Flowers JL. Thoracoscopic versus laparoscopic placement of defibrillator patches. Surg Laparosc Endosc 1996; 6: 91–7.

Gallin JI, Goldstein IM, Snyderman R. Inflammation: basic principles and clinical correlates. New York: Raven Press; 1988.

Schoen FJ, Harasaki H, Kim KM. Biomaterial-associated calcification: Pathology, mechanisms and strategis for prevention. J Biomed Mater Res 1988; 22: 11–36.

Becker AE, Becker MJ, Caludon DG. Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode. Circulation 1972; 46: 409–12.

Goldman BS, Macgregor DC. Management of infected pacemaker system. Clin Prog Pacing Electrphysiol 1984; 2: 220–35.

Morgan G, Gings W, Siddon H. Septicemia in patients with an endocardial pacemaker. Am J Cardiol 1979; 44: 221–4.

Bayliss CE, Beanlands DS, Baird RJ. The pacemaker-twinddlers syndrome: a new complication of implantable transvenous pacemakers. Can Med Assoc J 1968; 99: 371–3.

Mazzetti H, Dussaut A, Tentori C. Superior vena cava occlusion and syndrome related to pacemaker leads. Am Heart J 1993; 125: 831–7.

Kamenik B, Pehnec Z, Sinkovič A. Sindrom vene cave superior; redek zaplet trajne endokardialne elektrostimulacije srca. Zdrav Vestn 1999; 68: 727–30.

Madigan NP, Curtis JJ, Sanfelippo JF. Difficulty of extraction of chronically implanted tined ventricular endocardial leads. J Am Coll Cardiol 1984; 3: 724–31.

Byrd CL, Schwartz SJ, Hedin NB. Intravascular lead extraction using locking stylets and sheaths. PACE 1990; 13: 1871–2.

How to Cite
1.
Antonič J, Crnjac A. Surgical complications after pacemaker implantations. TEST ZdravVestn [Internet]. 1 [cited 5Aug.2024];74. Available from: http://vestnik-dev.szd.si/index.php/ZdravVest/article/view/2187
Section
Test Section