MOBILE MULTIMEDIA TERMINAL IN TRANSFUSION PRACTICE

  • Marko Meža Fakulteta za elektrotehniko Tržaška 25 1000 Ljubljana
  • Jurij Tasič Fakulteta za elektrotehniko Tržaška 25 1000 Ljubljana
  • Marko Breskvar Zavod Republike Slovenije za transfuzijsko medicino Šlajmerjeva 6 1000 Ljubljana
  • Irena Bricl Zavod Republike Slovenije za transfuzijsko medicino Šlajmerjeva 6 1000 Ljubljana
  • Primož Rožman Zavod Republike Slovenije za transfuzijsko medicino Šlajmerjeva 6 1000 Ljubljana
Keywords: patient identification, wristband, blood transfusion, sample labeling, bar code, identification errors, safety

Abstract

Background. Due to the administrative errors in the transfusion chain between the blood donor and the patient, transfusion errors still occur. Usually, they are caused by the misidentifications of the patient, his blood samples and respective blood components. A reliable identification can only be reached by an appropriate informatization of the whole process by implementation of information networks and communication technologies.

Methods. An information system covering all modern standards of safety and enabling integrity of patient records as well as faster and efficient transfusion was prepared. The system is enabling the rational use of the blood as well as assuring the obligatory haemoviligilance, as foreseen by the current law. The whole system is modular, consisting of terminals, supportive equipment, networking systems and servers. Additional hardware are the electronic code bar readers. Mobile terminals (Palm Pocket PCs) are wirelessly connected to the data network using the IEEE 802.11b WLAN technology in a wireless connection. All elements are included into the communication network with the servers contain data bases of blood donors, blood components and the patients; they execute the algorithms of the blood transfusion process support and enable the authentication. At the same time they enable the corresponding interfaces adapted to the users and terminals. For the connection of elements, corresponding interfaces are used.

Results. The application is supporting the whole system of ordering, issuing and transfusion of a blood component. Its main characteristics are the bar-coded wristband for patient identification, coding of the blood samples with the same bar code that is unmistakably connected with the patient, and electronic ordering of blood component via a handheld device at the patient’s side. By means of which identity of the patient and the blood component can be matched right before the intended transfusion. Similarly, the handheld device can also be used for the posttransfusion procedures including the transfusion report as well as adverse effects reports.

Conclusions. We expect that a similar system of transfusion safety assurance and haemovigilance is essential for the quality work at the hospital wards and will be set up soon, thereby enabling a safer and better transfusion therapy.

Downloads

Download data is not yet available.

References

McClelland DB. Treating a sick process. Transfusion 1998; 38: 999–1003.

Shulman IA, Lohr K, Derdiarian AK, Picukaric JM. Monitoring transfusionist practices: a strategy for improving transfusion safety. Transfusion 1994; 34: 11–5.

Baele PL, De B, Deneys V, Dupont E, Flament J, Lambermont M et al. Bedside transfusion errors. A prospective survey by the Belgium SAnGUIS Group. Vox Sang 1994; 66: 117–21.

Cox C, Enno A, Deveridge S, Seldon M, Richards R, Martens V et al. Remote electronic blood release system. Transfusion 1997; 37: 960–4.

Ibojie J, Urbaniak SJ. Comparing near misses with actual mistransfusion events: a more accurate reflection of transfusion errors. Br J Haematol 2000; 108: 458–60.

Linden JV, Wagner K, Voytovich AE, Sheehan J. Transfusion errors in New York State: an analysis of 10 years’ experience. Transfusion 2000; 40: 1207– 13.

Sharma RR, Kumar S, Agnihotri SK. Sources of preventable errors related to transfusion. Vox Sang 2001; 81: 37–41.

Rožman P. Preventivni ukrepi za izboljšanje varnosti transfuzije in virtualni transfuzijski laboratorij. Preventive measures for the improvement of the safety of blood transfusion and virtual transfusion laboratory. Zdrav Vestn 2002; 71: 245–9.

Dujardin PP, Salmi LR, Ingrand P. Errors in interpreting the pretransfusion bedside compatibility test: an experimental study. Vox Sang 2000; 78: 37–43.

Ingrand P, Surer P, Houssay D, Salmi LR. Reliability of the pretransfusion bedside compatibility test: association with transfusion practice and training. Transfusion 1998; 38: 1030–6.

Jensen NJ, Crosson JT. An automated system for bedside verification of the match between patient identification and blood unit identification. Transfusion 1996; 36: 216–21.

Lau FY, Wong R, Chui CH, Ng E, Cheng G. Improvement in transfusion safety using a specially designed transfusion wristband. Transfus Med 2000; 10: 121–4.

Renner SW, Howanitz PJ, Bachner P. Wristband identification error reporting in 712 hospitals. A College of American Pathologists’ Q-Probes study of quality issues in transfusion practice. Arch Pathol Lab Med 1993; 117: 573–7.

Marconi M, Sirchia G. Increasing transfusion safety by reducing human error. Curr Opin Hematol 2000; 7: 382–6.

Myhre BA, McRuer D. Human error – a significant cause of transfusion mortality. Transfusion 2000; 40: 879–85.

Williamson LM, Lowe S, Love EM, Cohen H, Soldan K, McClelland DB et al. Serious hazards of transfusion (SHOT) initiative: analysis of the first two annual reports. BMJ 1999; 319: 16–9.

Anon. Priporočilo o pripravi, uporabi in zagotavljanju kakovosti komponent krvi. Prevod. Ljubljana: Zavod RS za transfuzijo krvi: Informacijsko dokumentacijski center Sveta Evrope pri Narodni in univerzitetni knjižnici, 2000.

Anon. Pravilnik o veljavnosti Priporočila o pripravi, uporabi in zagotavljanju kakovosti komponent krvi. Ur List R Slovenije št. 64/19. 7. 2002, 6997.

How to Cite
1.
Meža M, Tasič J, Breskvar M, Bricl I, Rožman P. MOBILE MULTIMEDIA TERMINAL IN TRANSFUSION PRACTICE. TEST ZdravVestn [Internet]. 1 [cited 5Aug.2024];73. Available from: http://vestnik-dev.szd.si/index.php/ZdravVest/article/view/2441
Section
Review

Most read articles by the same author(s)